top of page

SDI 2460 & 2466 ACCELEROMETERS

Contact Us for a Quote
SDI Accelerometers at DigiKey
SDI Model 2460 accelerometer
SDI model 2466 accelerometer
Download the SDI 2460 & 2466 Datasheet

SDI’s Models 2460 and 2466 Low Cost Three-Axis MEMS DC Accelerometers are rugged plug-and-play measurement devices that provide reliable performance in most zero-to-medium frequency commercial and industrial applications, particularly where extremely low noise, and long-term stability are absolute requirements.  The 2460 includes a 3-foot integrated cable and are operationally identical to the 2466, which features a connector for easily customized cable lengths and positions.     

AVAILABLE

G-RANGES

± 2 g

± 5 g

± 10 g

± 25 g

± 50 g

± 100 g

± 200 g

± 400 g

  • Low Noise: 10 μg/rootHz Typical for ±2g Full Scale Versions

  • -55 to +125°C Operating Temperature Range 

  • Acceleration and Vibration Sensing Across Three Orthogonal Axes

  • Excellent Long-Term Stability

  • Flexible +8 to +32 VDC Power  

  • ±4V Differential Output or 0.5V to 4.5V Single Ended Output

  • Responds to frequencies from zero (DC) to 2000+ Hz

  • Low Impedance Outputs Support up to 2000 Feet of Cable

  • Simple Eight (8) Wire Connection, Choice of Integrated Cable or Connector

  • Rugged Anodized Aluminum Case

  • Fully Calibrated and Serialized for Traceability

Quick Links

1-Axis

3-Axis

Each SDI 2460 and 2466 triaxial accelerometer features three orthogonally mounted low noise accelerometers within a single, rugged, epoxy sealed, anodized aluminum case. Onboard voltage regulation and an internal voltage reference eliminate the need for precision power supplies. They are relatively insensitive to temperature changes and gradients. Individual axis directions are marked on the case with positive acceleration defined as acceleration in the direction of the axis arrow.  The robust, anodized aluminum case is epoxy sealed and can be mounted easily via two screws, an adhesive, or by attaching a magnet. 

ZERO TO MEDIUM FREQUENCY APPLICATIONS

SDI Accelerometer apps
g Range
Sensitivity, Differential
Frequency Response (Typ, 3 dB)
Frequency Response (Min, 3 dB)
Frequency Response (Typ, 5%)
Output Noise, Differential (RMS, Typ)
Max. Mechanical Shock (0.1 ms)
g
mV/g
Hz
Hz
Hz
μg/(root Hz)
g (peak)
±2
2000
0 – 525
0 – 300
0 – 250
10
2000
±5
800
0 – 800
0 – 420
0 – 400
15
2000
±10
400
0 – 1100
0 – 660
0 – 700
23
5000
±25
160
0 – 1750
0 – 1050
0 – 1300
38
5000
±50
80
0 – 2100
0 – 1400
0 – 1600
60
5000
±100
40
0 – 3000
0 – 1700
0 – 1700
121
5000
±200
20
0 – 3600
0 – 2100
0 – 1900
243
5000
±400
10
0 – 4200
0 – 2400
0 – 2000
475
5000

OPERATION

SDI Models 2460 and 2466 MEMS DC Accelerometers provide optimal performance when they are connected to instrumentation in a differential configuration using both the AOP and AON output signals, but they also support single ended operation for complete flexibility. 

 

These Accelerometers produce differential analog output voltage pairs (AON & AOP) which vary with acceleration.  The signal outputs are fully differential about a common mode voltage of approximately 2.5 volts.  At zero acceleration, the output differential voltage is nominally 0 volts DC; at ±full scale acceleration, the output is ±4 volts DC, respectively, as shown in the figure (below).  The output scale factor is independent from the supply voltage of +8 to +32 volts. 

 

When a differential connection is not possible, SDI recommends connecting the accelerometer to instrumentation in single ended mode by connecting AOP and GND to the instrumentation and leaving AON disconnected.  Keep in mind that the signal to noise ratio is reduced by half for a single-ended vs. a differential connection.

SDI Accelerometer differential and single ended output plots

PERFORMANCE - ALL VERSIONS

All Models: Unless otherwise specified, Vs=+8 to +32 VDC, TC=25°C, Differential Mode.  Span = ±g range = 8000 mV.

Note (1): For 2g thru 50g only; 100g and greater versions are tested and specified from -65 to +65g.

NOTICE:  Stresses greater than those listed may cause permanent damage to the device.  These are maximum stress ratings only.  Functional operation of the device at or above these conditions is not implied.

PACKAGE DIMENSIONS

SDI Model 2460

SDI 2460 case

SDI Model 2466

SDI 2466 case

Please see the data sheet for sensor location and other additional details. 

request your quote
Download the SDI 2460 & 2466 Datasheet

OPTIONAL ACCESSORIES

Model 2232 Magnetic Mount

  • 10 lbs / 4.6 KG pull force

  • Rated for use up to +/-50G

  • Low mass: 23 grams

SDI 2232 magnet mounting block

Model 2235 Stud Mount Adaptor Block

  • Stud mount Adaptor for any SDI module

  • Anodized 6061-T6 aluminum block

  • 6.2 grams, 0.7” x 1” footprint

SDI 2235 mounting block

SINGLE AXIS VERSIONS

The Silicon Designs Models 2210, 2260, and 2266 are the single axis versions of the 2460 and 2466 and come in multiple sizes to complement the triaxial configurations.  The 2210 comes in a traditional 1-inch square package with an integrated cable.  They are operationally identical to the 2260 and 2266, the small footprint devices designed for tight spaces. 

SDI model 2210, 2260 and 2266 accelerometers
bottom of page